Compliant storage and rental solutions for Phosphorus Trichloride (PCl3). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
Phosphorus Trichloride is a colorless, clear, fuming liquid with a strong odor. It is used in gasoline additives and textile finishing, and to make other chemicals, pesticides, dyestuffs, catalysts and plasticizers.
Acute toxicity, Oral (Category 2), H300 Acute toxicity, Inhalation (Category 2), H330 Skin corrosion (Category 1A), H314 Serious eye damage (Category 1), H318 Specific target organ toxicity - repeated exposure, Inhalation (Category 2), Respiratory Tract, H373 Short-term (acute) aquatic hazard (Category 3), H402
Dry Chemical fire suppression is recommended for Phosphorus Trichloride
Guidance: Dry Chemical fire suppression is generally recommended for Phosphorus Trichloride (PCl3). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Dry chemical Carbon dioxide (CO2)Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Phosphorus Trichloride should account for its listed hazards, climate control needs (Ambient), and segregation requirements. incompatible with many common oxidants such as: sodium peroxide, fluorine, chromyl chloride, iodine chloride, to name a few. Isopropanol can react with PCl3, forming toxic HCl gas.
Review Segregated storage for incompatible chemicals and Organic peroxide storage building when designing fire rating, containment, and building selection.
Properties: ) Appearance Form: liquid Color: clear b) Odor pungent c) Odor Threshold No data available d) pH No data available e) Melting point/freezing point Melting point/range: -112 °C (-170 °F) - lit. f) Initial boiling point and boiling range 74 - 78 °C 165 - 172 °F - lit.
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Phosphorus Trichloride in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Ambient. Compatibility notes: incompatible with many common oxidants such as: sodium peroxide, fluorine, chromyl chloride, iodine chloride, to name a few. Isopropanol can react with PCl3, forming toxic HCl gas. US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Phosphorus Trichloride is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.
Phosphorus Trichloride is listed as: Consult the SDS and applicable hazard classification. Acute toxicity, Oral (Category 2), H300 Acute toxicity, Inhalation (Category 2), H330 Skin corrosion (Category 1A), H314 Serious eye damage (Category 1), H318 Specific target organ toxicity - repeated exposure, Inhalation (Category 2), Respiratory Tract, H373 Short-term (acute) aquatic hazard (Category 3), H402
Dry Chemical fire suppression is generally recommended for Phosphorus Trichloride (PCl3). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Phosphorus Trichloride. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.